Smart energy management of combined ventilation systems in a nZEB

Autores/Authors: Rey-Hernández, J.M.; González-González, S.L.; San José-Alonso, J.F.; Tejero-González, A.; Velasco-Gómez, E.; Rey-Martínez, F.J.
Revista/Journal: E3S Web of Conferences 2019, 111, CLIMA 2019 Congress, 01050
Fecha Publicación/Publication Date: 13/08/2019
Impacto/Impact: SJR (2019): 0.166   ENERGY (miscellaneous)     Cuartil/Quartile: Q3
DOI: 10.1051/e3sconf/201911101050

Resumen/Abstract:

The high energy consumption, attached to a high energy demand in buildings, has led the development of several research projects with the target of reducing the energy consumption in the buildings. As a result of this high consumption, the increased CO2 emissions that have been generated in recent years, have reached alarming levels, which is why it is necessary to reduce the environmental impact which we are contributing to our planet through the use of energy.

The European Directive on Building Performance (EPBD 2018/844/EU), recently updated, requires new buildings to be close to the Zero Energy Buildings (nZEBs), increasing the use of renewable energies on-site, and also highlight how to get to improve the cost-effective renovation of existing buildings with the introduction of building control and automation systems (smart systems), as well as the energy savings and increase the efficiency of energy systems, by reducing CO2 emissions. The use of new renewable energy technologies integrated in buildings, with the aim of reducing the consumption of the facilities that all nZEB buildings must have, such as the ventilation system used as an Indoor Air Quality (IAQ) control technique.

In this study, the energy management of the enthalpy ventilation control system is analysed, where dynamic monitoring is going on in the building controlled through Supervisory Control And Data Acquisition (SCADA), in combination with different ventilation systems as free-cooling, heat recovery and geothermal energy of an Earth Air Heat eXchanger (EAHX), all of them as strategies implemented in a real nZEB building (LUCIA) located on the campus at the University of Valladolid, with the goal of improving energy efficiency in ventilation. In order to get this aims, monitoring data of several energy parameters (temperature, air velocity, air flow rate, enthalpy, etc.) are measurements, they allow us to perform a control of the combined ventilation systems to achieve a high IAQ and analyze an optimization of the energy efficiency of the all systems and to study of energy recovery and savings of carbon emissions that directly affect the reduction of the impact of climate change.

The results achieved are the energy efficiency of the building in ventilation and optimum system operation in cooling and heating mode. In addition, by controlling the ventilation, the IAQ of the nZEB building is improved.